The right battery size depends on two things: what it has to run, and for how long. You do not need software for a first estimate. Add up the energy, allow for what the battery and inverter cannot deliver, and round up to the next size.
Step 1: Decide what the battery is for
- Backup during power cuts. Only essential circuits: lights, Wi-Fi, a fridge, a TV, fans. This needs the least capacity.
- Evening and night use from solar. The battery stores the afternoon surplus and runs the home until the next morning.
- Both, or off-grid. The battery has to cover the whole night and some bad-weather days. This needs the most.
Step 2: Add up the energy in kWh
For each appliance, multiply its power by the hours it runs: watts × hours = watt-hours. Divide by 1,000 for kWh. Typical running power, as a starting point (check the label on the appliance):
| Appliance | Typical power |
|---|---|
| LED bulb | 5–10 W each |
| Wi-Fi router | 10–15 W |
| Laptop | 40–65 W |
| LED TV, 43 inch | 60–100 W |
| Fan | 40–75 W |
| Fridge or chest freezer | 100–200 W while the compressor runs; about 40–60 W on average over a day |
| Water pump, 0.5–1 HP | 370–750 W while running |
| Air conditioner, 1.5 HP | 1,100–1,400 W; less for inverter types at part load |
| Microwave | 1,000–1,200 W |
| Kettle | 1,800–2,200 W |
Step 3: Allow for usable energy and losses
Battery cycle life is usually rated at 80% depth of discharge, so plan to use about 80% of the rated kWh. The inverter also loses some energy converting DC to AC; 90% efficiency is a fair planning figure. So divide the energy you need by about 0.72 (0.8 × 0.9) to get the rated battery size.
Three worked examples
A. Essentials through a 10-hour power cut
| Load | Power × hours | Energy |
|---|---|---|
| LED lights | 100 W × 6 h | 0.6 kWh |
| Wi-Fi router | 10 W × 10 h | 0.1 kWh |
| TV | 100 W × 4 h | 0.4 kWh |
| Fridge | 50 W average × 10 h | 0.5 kWh |
| Fans | 60 W × 8 h | 0.5 kWh |
| Total | 2.1 kWh |
2.1 kWh ÷ 0.72 ≈ 2.9 kWh rated. A 5 kWh battery covers it with room to spare.
B. A family home from sunset to sunrise
| Load | Power × hours | Energy |
|---|---|---|
| LED lights | 100 W × 6 h | 0.6 kWh |
| TV and laptop | 150 W × 4 h | 0.6 kWh |
| Fridge | 50 W average × 13 h | 0.7 kWh |
| Fans | 120 W × 10 h | 1.2 kWh |
| Wi-Fi router | 10 W × 13 h | 0.1 kWh |
| Air conditioner | 1,000 W × 3 h | 3.0 kWh |
| Total | 6.2 kWh |
6.2 kWh ÷ 0.72 ≈ 8.6 kWh rated. A 10 kWh battery is the natural fit.
C. A larger home with air conditioning at night
| Load | Power × hours | Energy |
|---|---|---|
| Base loads (as in B, without AC) | 3.2 kWh | |
| Air conditioner | 1,200 W × 8 h | 9.6 kWh |
| Total | 12.8 kWh |
12.8 kWh ÷ 0.72 ≈ 17.8 kWh rated. A 20 kWh battery, or a 16 kWh battery if the air conditioner runs for fewer hours.
Step 4: Check power, not only energy
A battery also has a current limit. At 51.2 V, every kW of inverter output draws about 20 A from the battery. Our 5 kWh units are rated 50–70 A recommended and 100 A maximum; our 10–20 kWh units 100 A recommended and 200 A maximum. So a 5 kW inverter running at full power for hours is better served by a 10 kWh unit than a single 5 kWh unit, even if the energy adds up.
Quick guide
| Battery | Usable (80%) | Typical use |
|---|---|---|
| 5 kWh | 4.1 kWh | Essentials through a power cut; small homes and shops |
| 10 kWh | 8.2 kWh | A family home from sunset to sunrise |
| 16 kWh | 12.9 kWh | Larger homes, some air conditioning, longer outages |
| 20 kWh | 16.4 kWh | Whole-home use, small shops, off-grid |
Mistakes to avoid
- Counting rated kWh as usable kWh. Plan on about 80%.
- Forgetting the inverter. It loses energy in conversion and uses some power even with no load; check “no-load consumption” on its datasheet.
- Sizing energy but not current. Large loads need a battery, or two in parallel, that can deliver the current comfortably.
- Buying big on day one. Most of our 51.2 V batteries run up to 15 units in parallel, so a system can start at 5 or 10 kWh and grow.