Off-grid solar inverter
UD Pro+ series
Two 48 V off-grid inverters, 5 kW and 10 kW, with MPPT solar charging. Up to 9 units can work together in parallel, including three-phase setups, and the charging voltage can be set from 48 to 61 V.
5 / 10 kWrated output
48 Vbattery voltage
9units in parallel
120 Amax. solar charging
Highlights
Why installers choose UD Pro+ series
Parallel to 9 units
Expand the system with up to 9 units, three-phase parallel included.
Power-saving mode
High-efficiency design with a power-saving mode.
Auto restart
Restarts automatically when mains power comes back.
Lithium, Wi-Fi, dry contact
Supports lithium battery communication, external Wi-Fi and a dry contact.
Specifications
UD Pro+ series technical data
| Model | UD6348AMB | UD12548AMB |
|---|---|---|
| AC input | ||
| AC input voltage | 220 VAC (standard) | |
| Input voltage range | 90–275 VAC ± 3 V (normal mode), 170–275 VAC ± 3 V (UPS mode) | |
| Input frequency | 50 / 60 Hz ± 5% | |
| Output | ||
| Rated output power | 5,000 W | 10,000 W |
| Output voltage on mains | Same as the input voltage | |
| Output frequency on mains | Same as the input frequency | |
| Output voltage on battery | 220 VAC ± 10% | |
| Output frequency on battery | 50 or 60 Hz ± 1% | |
| Output waveform on battery | Pure sine wave | |
| Transfer time | ≤ 10 ms (UPS mode) / ≤ 20 ms (inverter mode) | |
| Load peak ratio | 3 : 1 (max.) | |
| Battery | ||
| Battery type | Lead-acid, gel, flooded or lithium (external) | |
| Battery voltage | 48 VDC | |
| Battery charging voltage | 56.4 VDC (settable 48–61 V) | |
| Solar & AC charger | ||
| Max. PV array power | 3,200 W | 6,400 W |
| Solar input voltage range | MPPT 60–150 VDC (200 VDC on request) | |
| Max. PV open-circuit voltage | 150 VDC (200 VDC on request) | |
| Max. solar charging current | 120 A | |
| Max. AC charging current | 50 A | 100 A |
| Protection & interface | ||
| Protection | On mains: input over-current fuse. On battery: overload, short-circuit and low-voltage protection, battery reverse-connection protection (fuse) | |
| Status display | AC voltage and frequency, PV voltage and current, output voltage and frequency, battery voltage, load current and more (page keys) | |
| Interface | RS232, lithium battery BMS communication, parallel interface, dry contact card | |
| Environment | ||
| Operating temperature | -10 to 50 °C | |
| Storage temperature | -15 to 45 °C | |
| Humidity | 20–95% (non-condensing) | |
| Noise | < 45 dB | |
| Size (L × W × H) | 527 × 330 × 149 mm | 545 × 400 × 200 mm |
Data from the 2026 inverter catalogue. Specifications may change; we confirm the current datasheet with every quotation.