White off-grid solar inverter with round grey display panel and side heat sink
Off-grid solar inverter

UD Pro series

Eight off-grid inverter models from 1.2 kW to 10 kW, for 12, 24 and 48 V lead-acid, gel or lithium batteries. Solar charging runs up to 120 A on the larger models, and the charging current can be set to suit the battery.

1.2–10 kWrated output
12 / 24 / 48 Vbattery voltage
120 Amax. solar charging (5 kW +)
3 : 1load peak ratio
Highlights

Why installers choose UD Pro series

Lead-acid or lithium

Works with lead-acid, gel, flooded and lithium batteries, with BMS for lithium.

Adjustable charging current

Set the charging current to suit the battery and the application.

Generator start

Optional signal to start a generator automatically.

Wi-Fi or GPRS

Optional Wi-Fi or GPRS monitoring.

Specifications

UD Pro series technical data

Swipe sideways to see all models →

ModelUD1512AMUD2024AMUD3824AMUD5024AM / UD5048AMUD6348AMUD8048AMUD10048AMUD12548AM
AC input
AC input voltage220 VAC (standard)
Input voltage range154–264 VAC ± 3 V (normal mode), 185–264 VAC ± 3 V (UPS mode)
Input frequency50 / 60 Hz ± 5%
Output
Rated output power1,200 W2,400 W3,040 W4,000 W5,000 W6,400 W8,000 W10,000 W
Output voltage on mainsSame as the input voltage
Output frequency on mainsSame as the input frequency
Output voltage on battery220 VAC ± 10%
Output frequency on battery50 or 60 Hz ± 1%
Output waveform on batteryPure sine wave
Transfer time≤ 10 ms (UPS mode) / ≤ 20 ms (inverter mode)
Load peak ratio3 : 1 (max.)
Battery
Battery typeLead-acid, gel, flooded or lithium (external)
Battery voltage12 VDC24 VDC24 VDC24 / 48 VDC48 VDC48 VDC48 VDC48 VDC
Battery charging voltage13.7 VDC27.4 VDC27.4 VDC27.4 / 54.8 VDC54.8 VDC54.8 VDC54.8 VDC54.8 VDC
Solar & AC charger
Max. PV array power800 W1,600 W1,600 W1,600 W (24 V) / 3,200 W (48 V)6,400 W6,400 W6,400 W6,400 W
Solar input voltage range24 V models: MPPT 30–150 VDC · 48 V models: MPPT 60–150 VDC
Max. PV open-circuit voltage12 V: 50 VDC (PWM) · 24 V: 150 VDC (MPPT) · 48 V: 150 VDC (MPPT)
Max. solar charging current60 A60 A60 A60 A120 A120 A120 A120 A
Max. AC charging current50 A50 A63 A83 / 41 A52 A66 A83 A104 A
Protection & display
ProtectionOn mains: input over-current fuse. On battery: overload, short-circuit and low-voltage protection, battery reverse-connection protection
Status displayAC voltage and frequency, PV voltage and current, output voltage and frequency, battery voltage, load current and more (page keys)
Environment
Operating temperature-10 to 50 °C
Storage temperature-15 to 45 °C
Noise< 45 dB

Data from the 2026 inverter catalogue. Specifications may change; we confirm the current datasheet with every quotation.