Off-grid solar inverter
JU series
Four off-grid inverters from 3 kW (24 V battery) to 8 kW (48 V battery). The built-in MPPT charger accepts up to 245 VDC and charges at up to 100 A. A 110 V version is available on request.
3–8 kWrated output
24 / 48 Vbattery voltage
245 V · 100 AMPPT charger
3 : 1load peak ratio
Highlights
Why installers choose JU series
Built-in MPPT
Solar input up to 245 VDC, charging at up to 100 A.
Low no-load loss
Uses less than half the no-load power of a high-frequency unit of the same rating.
Short-circuit protection
Output short-circuit protection as standard.
RS232 and BMS
RS232 communication as standard; BMS for lithium batteries.
Specifications
JU series technical data
Swipe sideways to see all models →
| Model | JU3824AM8V | JU5048AM8V | JU6348AM8V | JU10048AM8V |
|---|---|---|---|---|
| AC input | ||||
| AC input voltage | 220 VAC (standard) | |||
| Input voltage range | 154–264 VAC ± 3 V (normal mode), 185–264 VAC ± 3 V (UPS mode); 110 V version: 77–132 VAC ± 3 V (normal), 92–132 VAC ± 3 V (UPS) | |||
| Input frequency | 50 / 60 Hz ± 5% | |||
| Output | ||||
| Rated output power | 3,000 W | 4,000 W | 5,000 W | 8,000 W |
| Output voltage on mains | Same as the input voltage | |||
| Output frequency on mains | Same as the input frequency | |||
| Output voltage on battery | 220 VAC ± 10% (110 VAC ± 10% on request) | |||
| Output frequency on battery | 50 or 60 Hz ± 1% | |||
| Output waveform on battery | Pure sine wave | |||
| Transfer time | ≤ 10 ms (UPS mode) / ≤ 20 ms (inverter mode) | |||
| Load peak ratio | 3 : 1 (max.) | |||
| Battery | ||||
| Battery type | Lead-acid, gel, flooded or lithium (external) | |||
| Battery voltage | 24 VDC | 48 VDC | 48 VDC | 48 VDC |
| Battery charging voltage | 27.4 VDC | 54.8 VDC | 54.8 VDC | 54.8 VDC |
| Solar & AC charger | ||||
| Max. PV array power | 2,700 W | 5,400 W | 5,400 W | 5,400 W |
| Solar input voltage range | 30–245 VDC | 60–245 VDC | 60–245 VDC | 60–245 VDC |
| Max. PV open-circuit voltage | 245 VDC | |||
| Max. solar charging current | 100 A | |||
| Max. AC charging current | 63 A | 41 A | 52 A | 83 A |
| Protection & display | ||||
| Protection | On mains: input over-current fuse. On battery: overload, short-circuit and low-voltage protection, battery reverse-connection protection | |||
| Status display | AC voltage and frequency, PV voltage and current, output voltage and frequency, battery voltage, load current and more (page keys) | |||
| Environment | ||||
| Operating temperature | -10 to 50 °C | |||
| Storage temperature | -15 to 45 °C | |||
| Noise | < 45 dB | |||
Data from the 2026 inverter catalogue. Specifications may change; we confirm the current datasheet with every quotation.