Small off-grid inverter
UD series
Five small off-grid inverters from 400 W to 1.6 kW for 12 V and 24 V batteries: lead-acid, gel or lithium. A solar charger up to 60 A is built in.
0.4–1.6 kWrated output
12 / 24 Vbattery voltage
60 Amax. solar charging
< 45 dBnoise
Highlights
Why installers choose UD series
Pure sine wave
Clean 220 VAC output for home appliances.
Lead-acid or lithium
Works with lead-acid, gel, flooded and lithium batteries, with BMS for lithium.
Generator start
Optional signal to start a generator automatically.
Self-diagnosis
DC start and automatic self-diagnosis.
Specifications
UD series technical data
Swipe sideways to see all models →
| Model | UD0512AP | UD0812AP | UD1012AP | UD1512AP / UD1524AP | UD2024AP |
|---|---|---|---|---|---|
| AC input | |||||
| AC input voltage | 220 VAC (standard) | ||||
| Input voltage range | 154–264 VAC ± 3 V (normal mode), 185–264 VAC ± 3 V (UPS mode) | ||||
| Input frequency | 50 / 60 Hz ± 5% | ||||
| Output | |||||
| Rated output power | 400 W | 640 W | 800 W | 1,200 W | 1,600 W |
| Output voltage on mains | Same as the input voltage | ||||
| Output frequency on mains | Same as the input frequency | ||||
| Output voltage on battery | 220 VAC ± 10% | ||||
| Output frequency on battery | 50 or 60 Hz ± 1% | ||||
| Output waveform on battery | Pure sine wave | ||||
| Transfer time | ≤ 10 ms (UPS mode) / ≤ 20 ms (inverter mode) | ||||
| Load peak ratio | 3 : 1 (max.) | ||||
| Battery | |||||
| Battery type | Lead-acid, gel, flooded or lithium (external) | ||||
| Battery voltage | 12 VDC | 12 VDC | 12 VDC | 12 / 24 VDC | 24 VDC |
| Battery charging voltage | 13.7 VDC | 13.7 VDC | 13.7 VDC | 13.7 / 27.4 VDC | 27.4 VDC |
| Solar & AC charger | |||||
| Max. PV array power | 12 V: 800 W · 24 V: 1,600 W | ||||
| Solar input voltage range | 12 V: PWM 15–50 VDC · 24 V: PWM 30–105 VDC | ||||
| Max. PV open-circuit voltage | 12 V: 50 VDC · 24 V: 105 VDC | ||||
| Max. solar charging current | 60 A | ||||
| Max. AC charging current | 13 A | 21 A | 27 A | 40 / 20 A | 27 A |
| Protection & display | |||||
| Protection | On mains: input over-current fuse. On battery: overload, short-circuit and low-voltage protection, battery reverse-connection protection | ||||
| Status display | AC voltage and frequency, PV voltage and current, output voltage and frequency, battery voltage, load current and more (page keys) | ||||
| Environment | |||||
| Operating temperature | -10 to 50 °C | ||||
| Storage temperature | -15 to 45 °C | ||||
| Noise | < 45 dB | ||||
Data from the 2026 inverter catalogue. Specifications may change; we confirm the current datasheet with every quotation.