Hybrid solar inverter
QD series
Four hybrid inverters from 1.6 kW (12 V battery) to 11 kW (48 V battery). All four have MPPT solar chargers and can run grid-connected; the 11 kW model has two MPPT inputs and supports parallel operation.
1.6–11 kWrated power
12 / 24 / 48 Vbattery voltage
2 × 8,500 Wmax. PV input (11 kW)
98%peak efficiency
Highlights
Why installers choose QD series
Lithium auto-restart
Wakes the lithium battery automatically for easier charging.
Smart power modes
Shares the load between solar, grid and battery.
Reverse-connection protection
Battery reverse-connection protection with a fuse switch.
Runs without a battery
Can work on solar and grid alone to lower system cost.
Specifications
QD series technical data
Swipe sideways to see all models →
| Model | QD2012MH | QD3624MH | QD6248MH | QD12048MH |
|---|---|---|---|---|
| AC input | ||||
| Rated input voltage | 220 / 230 / 240 VAC | |||
| Input voltage range | 90–280 VAC ± 3 V (normal mode), 170–280 VAC ± 3 V (UPS mode) | |||
| Input frequency | 50 / 60 Hz | |||
| Output | ||||
| Rated power (battery) | 1,600 W | 3,600 W | 6,200 W | 11,000 W |
| PV inverter output power | 2,000 W | 3,600 W | 6,200 W | 12,000 W |
| Output voltage | 220 / 230 / 240 VAC ± 5% | |||
| Output frequency | 50 / 60 Hz ± 0.1% | |||
| Output waveform | Pure sine wave | |||
| Transfer time | ≤ 10 ms (UPS mode) / ≤ 20 ms (inverter mode) | |||
| Peak power | 3,200 VA | 7,200 VA | 12,400 VA | 24,000 VA |
| Grid-connected operation | ||||
| Grid output voltage | 220 / 230 / 240 VAC | |||
| Grid voltage range | 100–280 VAC | |||
| Grid frequency range | 47–53 ± 1 Hz / 57–62 ± 1 Hz | |||
| Rated output current | 8.7 A | 15.7 A | 26.9 A | 52.2 A |
| Power factor | > 0.99 | |||
| Peak efficiency (DC/AC) | 98% | |||
| Battery | ||||
| Rated battery voltage | 12 VDC | 24 VDC | 48 VDC | 48 VDC |
| Constant charging voltage (settable) | 14.1 VDC | 28.2 VDC | 56.4 VDC | 56.4 VDC |
| Float charging voltage (settable) | 13.5 VDC | 27 VDC | 54 VDC | 54 VDC |
| Solar & AC charger | ||||
| PV charging mode | MPPT | MPPT | MPPT | Dual MPPT |
| Max. PV input power | 3,000 W | 5,000 W | 8,500 W | 2 × 8,500 W |
| MPPT voltage range | 60–500 VDC | 60–500 VDC | 60–500 VDC | 90–500 VDC |
| Optimal Vmp range | 300–400 VDC | 300–430 VDC | 360–430 VDC | 360–430 VDC |
| Max. PV input voltage | 500 VDC | |||
| Max. PV input current | 15 A | 15 A | 27 A | 27 A / 27 A |
| Max. PV charging current | 100 A | 120 A | 120 A | 150 A |
| Max. AC charging current | 80 A | 100 A | 100 A | 150 A |
| Max. charging current | 100 A | 120 A | 120 A | 150 A |
| Display & interface | ||||
| Display | LCD: operating mode, load, input and output | |||
| RS232 | Baud rate 2400 | |||
| Expansion slot | Lithium battery BMS communication card, Wi-Fi card, dry contact card | |||
| Parallel operation | No | No | No | Yes |
| Environment | ||||
| Operating temperature | -10 to 50 °C | |||
| Storage temperature | -10 to 60 °C | |||
| Humidity | 20–90% (non-condensing) | |||
| Noise | ≤ 50 dB | |||
Data from the 2026 inverter catalogue. Specifications may change; we confirm the current datasheet with every quotation.