White wall-mounted hybrid solar inverter with grey hexagon LCD panel
Hybrid solar inverter

QD series

Four hybrid inverters from 1.6 kW (12 V battery) to 11 kW (48 V battery). All four have MPPT solar chargers and can run grid-connected; the 11 kW model has two MPPT inputs and supports parallel operation.

1.6–11 kWrated power
12 / 24 / 48 Vbattery voltage
2 × 8,500 Wmax. PV input (11 kW)
98%peak efficiency
Highlights

Why installers choose QD series

Lithium auto-restart

Wakes the lithium battery automatically for easier charging.

Smart power modes

Shares the load between solar, grid and battery.

Reverse-connection protection

Battery reverse-connection protection with a fuse switch.

Runs without a battery

Can work on solar and grid alone to lower system cost.

Specifications

QD series technical data

Swipe sideways to see all models →

ModelQD2012MHQD3624MHQD6248MHQD12048MH
AC input
Rated input voltage220 / 230 / 240 VAC
Input voltage range90–280 VAC ± 3 V (normal mode), 170–280 VAC ± 3 V (UPS mode)
Input frequency50 / 60 Hz
Output
Rated power (battery)1,600 W3,600 W6,200 W11,000 W
PV inverter output power2,000 W3,600 W6,200 W12,000 W
Output voltage220 / 230 / 240 VAC ± 5%
Output frequency50 / 60 Hz ± 0.1%
Output waveformPure sine wave
Transfer time≤ 10 ms (UPS mode) / ≤ 20 ms (inverter mode)
Peak power3,200 VA7,200 VA12,400 VA24,000 VA
Grid-connected operation
Grid output voltage220 / 230 / 240 VAC
Grid voltage range100–280 VAC
Grid frequency range47–53 ± 1 Hz / 57–62 ± 1 Hz
Rated output current8.7 A15.7 A26.9 A52.2 A
Power factor> 0.99
Peak efficiency (DC/AC)98%
Battery
Rated battery voltage12 VDC24 VDC48 VDC48 VDC
Constant charging voltage (settable)14.1 VDC28.2 VDC56.4 VDC56.4 VDC
Float charging voltage (settable)13.5 VDC27 VDC54 VDC54 VDC
Solar & AC charger
PV charging modeMPPTMPPTMPPTDual MPPT
Max. PV input power3,000 W5,000 W8,500 W2 × 8,500 W
MPPT voltage range60–500 VDC60–500 VDC60–500 VDC90–500 VDC
Optimal Vmp range300–400 VDC300–430 VDC360–430 VDC360–430 VDC
Max. PV input voltage500 VDC
Max. PV input current15 A15 A27 A27 A / 27 A
Max. PV charging current100 A120 A120 A150 A
Max. AC charging current80 A100 A100 A150 A
Max. charging current100 A120 A120 A150 A
Display & interface
DisplayLCD: operating mode, load, input and output
RS232Baud rate 2400
Expansion slotLithium battery BMS communication card, Wi-Fi card, dry contact card
Parallel operationNoNoNoYes
Environment
Operating temperature-10 to 50 °C
Storage temperature-10 to 60 °C
Humidity20–90% (non-condensing)
Noise≤ 50 dB

Data from the 2026 inverter catalogue. Specifications may change; we confirm the current datasheet with every quotation.