Hybrid inverters from 4 kW (24 V battery) to 11 kW (48 V battery) with safety switches for input and output built into the case. The 6.2 kW and 11 kW models run up to 9 units in parallel.
4–11 kWrated power
24 / 48 Vbattery voltage
9units in parallel (48 V)
98%peak efficiency
Highlights
Why installers choose IU series
Built-in safety switches
Input and output switches on the unit for safer installation and service.
More solar power
Higher PV input current and power, and more inverter power in PV mode.
Solar and grid together
PV and mains complement each other in hybrid mode for better use of solar.
Lightning and EMI protection
Lightning and high-voltage protection, with an EMI filter to reduce interference.
Specifications
IU series technical data
Swipe sideways to see all models →
| Model | IU4024SMH | IU6248SMH | IU11048SMH |
|---|---|---|---|
| AC input | |||
| Rated input voltage | 220 / 230 / 240 VAC | ||
| Input voltage range | 90–280 VAC ± 3 V (normal mode), 170–280 VAC ± 3 V (UPS mode) | ||
| Input frequency | 50 / 60 Hz ± 5% | ||
| Output | |||
| Rated power (battery) | 4,000 W | 6,200 W | 11,000 W |
| PV inverter output power | 4,500 W | 6,500 W | 12,000 W |
| Output voltage | 220 / 230 / 240 VAC ± 5% | ||
| Output frequency | 50 / 60 Hz ± 0.1% | ||
| Output waveform | Pure sine wave | ||
| Transfer time | ≤ 10 ms (UPS mode) / ≤ 20 ms (inverter mode) | ||
| Peak power | 8,000 VA | 12,400 VA | 22,000 VA |
| Grid-connected operation | |||
| Grid output voltage | 220 / 230 / 240 VAC | ||
| Grid voltage range | 170–265 VAC | ||
| Grid frequency range | 49–51 ± 1 Hz / 59–61 ± 1 Hz | ||
| Rated output current | 17.4 A | 26.9 A | 47.8 A |
| Power factor | > 0.99 | ||
| Peak efficiency (DC/AC) | 98% | ||
| Battery | |||
| Rated battery voltage | 24 VDC | 48 VDC | 48 VDC |
| Constant charging voltage (settable) | 28.2 VDC | 56.4 VDC | 56.4 VDC |
| Float charging voltage (settable) | 27 VDC | 54 VDC | 54 VDC |
| Solar & AC charger | |||
| PV charging mode | MPPT | MPPT | Dual MPPT |
| Max. PV input power | 6,500 W | 8,500 W | 2 × 7,500 W |
| MPPT voltage range | 60–500 VDC | 60–500 VDC | 90–500 VDC |
| Optimal Vmp range | 360–430 VDC | ||
| Max. PV input voltage | 500 VDC | ||
| Max. PV input current | 27 A | 27 A | 27 A / 27 A |
| Max. PV charging current | 120 A | 120 A | 150 A |
| Max. AC charging current | 100 A | 100 A | 150 A |
| Max. charging current | 120 A | 150 A | 150 A |
| Display & interface | |||
| Display | LCD: operating mode, load, input and output | ||
| RS232 | Baud rate 2400 | ||
| Expansion slot | Lithium battery BMS communication card, Wi-Fi card, dry contact card | ||
| Parallel operation | No | Up to 9 units | Up to 9 units |
| Environment | |||
| Operating temperature | -10 to 50 °C | ||
| Storage temperature | -10 to 60 °C | ||
| Humidity | 20–90% (non-condensing) | ||
| Noise | ≤ 50 dB | ||
Data from the 2026 inverter catalogue. Specifications may change; we confirm the current datasheet with every quotation.