White hybrid solar inverter with LCD panel, side heat sink and input/output switches at the bottom
Hybrid solar inverter

IU series

Hybrid inverters from 4 kW (24 V battery) to 11 kW (48 V battery) with safety switches for input and output built into the case. The 6.2 kW and 11 kW models run up to 9 units in parallel.

4–11 kWrated power
24 / 48 Vbattery voltage
9units in parallel (48 V)
98%peak efficiency
Highlights

Why installers choose IU series

Built-in safety switches

Input and output switches on the unit for safer installation and service.

More solar power

Higher PV input current and power, and more inverter power in PV mode.

Solar and grid together

PV and mains complement each other in hybrid mode for better use of solar.

Lightning and EMI protection

Lightning and high-voltage protection, with an EMI filter to reduce interference.

Specifications

IU series technical data

Swipe sideways to see all models →

ModelIU4024SMHIU6248SMHIU11048SMH
AC input
Rated input voltage220 / 230 / 240 VAC
Input voltage range90–280 VAC ± 3 V (normal mode), 170–280 VAC ± 3 V (UPS mode)
Input frequency50 / 60 Hz ± 5%
Output
Rated power (battery)4,000 W6,200 W11,000 W
PV inverter output power4,500 W6,500 W12,000 W
Output voltage220 / 230 / 240 VAC ± 5%
Output frequency50 / 60 Hz ± 0.1%
Output waveformPure sine wave
Transfer time≤ 10 ms (UPS mode) / ≤ 20 ms (inverter mode)
Peak power8,000 VA12,400 VA22,000 VA
Grid-connected operation
Grid output voltage220 / 230 / 240 VAC
Grid voltage range170–265 VAC
Grid frequency range49–51 ± 1 Hz / 59–61 ± 1 Hz
Rated output current17.4 A26.9 A47.8 A
Power factor> 0.99
Peak efficiency (DC/AC)98%
Battery
Rated battery voltage24 VDC48 VDC48 VDC
Constant charging voltage (settable)28.2 VDC56.4 VDC56.4 VDC
Float charging voltage (settable)27 VDC54 VDC54 VDC
Solar & AC charger
PV charging modeMPPTMPPTDual MPPT
Max. PV input power6,500 W8,500 W2 × 7,500 W
MPPT voltage range60–500 VDC60–500 VDC90–500 VDC
Optimal Vmp range360–430 VDC
Max. PV input voltage500 VDC
Max. PV input current27 A27 A27 A / 27 A
Max. PV charging current120 A120 A150 A
Max. AC charging current100 A100 A150 A
Max. charging current120 A150 A150 A
Display & interface
DisplayLCD: operating mode, load, input and output
RS232Baud rate 2400
Expansion slotLithium battery BMS communication card, Wi-Fi card, dry contact card
Parallel operationNoUp to 9 unitsUp to 9 units
Environment
Operating temperature-10 to 50 °C
Storage temperature-10 to 60 °C
Humidity20–90% (non-condensing)
Noise≤ 50 dB

Data from the 2026 inverter catalogue. Specifications may change; we confirm the current datasheet with every quotation.

WhatsApp