Hybrid solar inverter
ED series
Six models from 1.6 kW (12 V battery) to 11 kW (48 V battery) in a slim case. The 4 kW and larger models can also run grid-connected, and the 8.6 kW and 11 kW models have two MPPT inputs and support parallel operation.
1.6–11 kWrated power
12 / 24 / 48 Vbattery voltage
2 × 5,500 Wmax. PV input (8.6 / 11 kW)
98%peak efficiency
Highlights
Why installers choose ED series
Low no-load loss
Uses less than half the no-load power of a high-frequency unit of the same rating.
Slim body
Easy to install and to ship.
Stable output
Pure sine wave with high output-voltage accuracy for your appliances.
Wi-Fi and BMS
External Wi-Fi and BMS communication for lithium batteries.
Specifications
ED series technical data
Swipe sideways to see all models →
| Model | ED2012EMH | ED3024EMH | ED4024EMH | ED6248EMH | ED8648EMH | ED11048EMH |
|---|---|---|---|---|---|---|
| AC input | ||||||
| Rated input voltage | 220 / 230 / 240 VAC | |||||
| Input voltage range | 90–280 VAC ± 3 V (normal mode), 170–280 VAC ± 3 V (UPS mode) | |||||
| Input frequency | 50 / 60 Hz (auto-adapting) | |||||
| Output | ||||||
| Rated power (battery) | 1,600 W | 3,000 W | 4,000 W | 6,200 W | 8,600 W | 11,000 W |
| PV inverter output power | 1,600 W | 3,000 W | 4,500 W | 6,200 W | 11,000 W | 12,000 W |
| Output voltage | 220 / 230 / 240 VAC ± 5% | |||||
| Output frequency | 50 / 60 Hz ± 0.1% | |||||
| Output waveform | Pure sine wave | |||||
| Transfer time | ≤ 10 ms (UPS mode) / ≤ 20 ms (inverter mode) | |||||
| Peak power | 3,200 VA | 6,000 VA | 8,000 VA | 12,400 VA | 17,200 VA | 22,000 VA |
| Grid-connected operation | ||||||
| Grid-connected mode | No | No | Yes | Yes | Yes | Yes |
| Grid output voltage | — | — | 220 / 230 / 240 VAC | 220 / 230 / 240 VAC | 220 / 230 / 240 VAC | 220 / 230 / 240 VAC |
| Grid voltage range | — | — | 100–280 VAC | 100–280 VAC | 100–280 VAC | 100–280 VAC |
| Grid frequency range | — | — | 47–53 ± 1 Hz / 57–62 ± 1 Hz | 47–53 ± 1 Hz / 57–62 ± 1 Hz | 47–53 ± 1 Hz / 57–62 ± 1 Hz | 47–53 ± 1 Hz / 57–62 ± 1 Hz |
| Rated output current | — | — | 17.4 A | 26.9 A | 37.4 A | 47.8 A |
| Power factor | — | — | > 0.99 | > 0.99 | > 0.99 | > 0.99 |
| Peak efficiency (DC/AC) | — | — | 98% | 98% | 98% | 98% |
| Battery | ||||||
| Rated battery voltage | 12 VDC | 24 VDC | 24 VDC | 48 VDC | 48 VDC | 48 VDC |
| Constant charging voltage (settable) | 14.1 VDC | 28.2 VDC | 28.2 VDC | 56.4 VDC | 56.4 VDC | 56.4 VDC |
| Float charging voltage (settable) | 13.5 VDC | 27 VDC | 27 VDC | 54 VDC | 54 VDC | 54 VDC |
| Solar & AC charger | ||||||
| PV charging mode | MPPT | MPPT | MPPT | MPPT | Dual MPPT | Dual MPPT |
| Max. PV input power | 2,000 W | 3,000 W | — | 6,200 W | 2 × 5,500 W | 2 × 5,500 W |
| MPPT voltage range | 30–500 VDC | 30–500 VDC | 60–500 VDC | 60–500 VDC | 90–500 VDC | 90–500 VDC |
| Optimal Vmp range | 300–400 VDC | |||||
| Max. PV input voltage | 500 VDC | |||||
| Max. PV input current | 13 A | 13 A | 18 A | 18 A | 18 A / 18 A | 18 A / 18 A |
| Max. PV charging current | 100 A | 100 A | 120 A | 120 A | 150 A | 150 A |
| Max. AC charging current | 60 A | 60 A | 100 A | 100 A | 120 A | 150 A |
| Max. charging current | 100 A | 100 A | 120 A | 120 A | 150 A | 150 A |
| Display & interface | ||||||
| Display | LCD: operating mode, load, input and output | |||||
| RS232 | Baud rate 2400 | |||||
| Expansion slot | Lithium battery BMS communication card, Wi-Fi card, dry contact card | |||||
| Parallel operation | No | No | No | No | Yes | Yes |
| Environment | ||||||
| Operating temperature | -10 to 50 °C | |||||
| Storage temperature | -10 to 60 °C | |||||
| Humidity | 20–90% (non-condensing) | |||||
| Noise | ≤ 50 dB | |||||
Data from the 2026 inverter catalogue. Specifications may change; we confirm the current datasheet with every quotation.